Accessibility Support
Out of the box, the Telerik and Kendo UI ProgressBar provides extensive accessibility support and enables users with disabilities to acquire complete control over its features.
The ProgressBar is compliant with the Web Content Accessibility Guidelines (WCAG) 2.2 standards and Section 508 requirements, follows the Web Accessibility Initiative - Accessible Rich Internet Applications (WAI-ARIA) best practices for implementing the keyboard navigation for its component
role, provides options for managing its focus and is tested against the most popular screen readers.
WAI-ARIA
This section lists the selectors, attributes, and behavior patterns supported by the component and its composite elements, if any.
Selector | Attribute | Usage |
---|---|---|
.k-progressbar | role=progressbar | Sets the proper role for ProgressBar. |
aria-label or aria-labelledby | The Progressbar needs an accessible name to be assigned to it. | |
aria-valuenow | Only present and required if the value is not indeterminate. Set to a decimal value between 0, or aria-valuemin if present, and aria-valuemax indicating the current value of the progress bar. | |
aria-valuemin | Set to a decimal value representing the minimum value, and less than aria-valuemax. If not present, the default value is 0. | |
aria-valuemax | Set to a decimal value representing the maximum value, and greater than aria-valuemin. If not present, the default value is 100. |
Testing
The ProgressBar has been extensively tested automatically with axe-core and manually with the most popular screen readers.
Screen Readers
The ProgressBar has been tested with the following screen readers and browsers combinations:
Environment | Tool |
---|---|
Firefox | NVDA |
Chrome | JAWS |
Microsoft Edge | JAWS |